Gillis Ag Systems Home About Us Production Systems Products Technical Service Links
Gillis Ag Systems
Gillis Agricultural Systems

Shop Online
Shop our Online Store!
Infraconic Radiant Heater Specifications


  Infraconic
I-10
Infraconic
I-17
Infraconic
I-3
Infraconic
I-5
Heat Rating
Btu/h Rating (Btu/h) 10,400 17,100 2,800 5,200
Pig Coverage
Farrowing - - 1 unit per 2 crates -
Nursery/Wean to Finish 150 170 - 30
Configurations Available
Modulating Yes Yes Yes Yes
Spark Ignition Yes Yes - -
Installation Height
Installation Height (ft.) 4 5 2 3
Fuel Consumption (max)
LPG (lbs./hr.) 0.48 0.80 0.16 0.24
NG (cu. ft./hr.) 10.4 17.1 3.4 5.2
Inlet Gas Pressure
LPG (PSIG) 5 5 5 5
NG (PSIG) 5 5 5 5
Ventilation Requirements
Ventilation (CFM) 122 200 40 60
Temperature Controls Available
Individual Thermostat Modulating only Modulating only - -
Wired to House Control Yes Yes - Yes
Zone (panel sold separately) Yes Yes Yes Yes
Electrical Supply
Electrical Requirements - Modulating (Volts/Hz) None None None None
Electrical Requirements - Spark (Volts/Hz) 115 / 60 115 / 60 - -
Minimum Clearance to Combustibles
Below (ft.) 3.5 3.5 2.0 3.0
Sides (ft.) 3 3 2.5 3
Top (ft.) 3 3 2.5 2.5
Dimensions
Canopy Diameter (in.) 16.9 16.9 7.7 11.8
Height (in.) 8.8 8.8 4.7 5.0
Weight
Net Weight (lbs.) 5.6 5.6 1.4 1.7
Add'l Features/Options
Gas Hose - 1/4" x 6 ft Std. Std. Std. Std.
Inlet Air Filter - Spark Std. Std. Std. Std.
Regulator (Zone Control Panel) Opt. Opt. Opt. Opt.